Total Access 600 Series System Manual Section 4 User Interface Guide
61200624L1-1B © 2004 ADTRAN, Inc. 83
INTERFACES (FXS) > CONFIG > PORT
Indicates the port of the FXS module.
INTERFACES (FXS) > CONFIG > MODE
Choices are given below. Default is L
OOP
S
TART
.
INTERFACES (FXS) > CONFIG > TX (
d
B)
Sets the TX direction level points. This signal will change the volume of the voice. TX (dB) is the signal
that is transmitted out the T1, with 0 dB being the strongest. If the volume is too loud across the T1, this
number should be increased. A higher number indicates more attenuation which equals lower volume. The
value entered must be less than 10 dB. Default is
6.0 dB.
INTERFACES (FXS) > CONFIG > RX (
d
B)
Sets the RX direction level points. This signal will change the volume of the voice. A higher number
indicates more attenuation which equals lower volume. The value entered must be less than 10 dB. Default
is
3.0 dB. The maximum signal is 0.0 dB.
This mode must match the network configuration and/or how each port is being used. Each
port on the FXS Module is independent and should be set accordingly.
L
OOP
S
TART
Sets the port to use FXS loop start signaling on the T-span and loop start
supervision on the analog 2-wire interface.
G
ROUND
S
TART
Sets the port to use FXS ground start signaling on the T-span and ground
start supervision on the analog 2-wire interface.
TR08 S
INGLE
Sets the port to use Single Party Channel Unit signaling on the T-span
(as defined by TR-TSY-000008) and loop start supervision on the
analog 2-wire interface.Only available when using a T1 network
interface.
TR08 UVG
Sets the port to use Universal Voice Grade signaling on the T-span (as
defined by TR-TSY-000008) and either loop start or ground start
supervision on the analog 2-wire interface. Only available when using a
T1 network interface.
DPO
Sets the port to use Dial Pulse signaling to originate dialed numbers.
Only available when using a T1 network interface.
T
ANDEM
(E&M)
Sets the port to use E&M signaling on the T-span and either loop start or
ground start supervision on the analog 2-wire interface. See the
T
ANDEM
submenus for more information. Only available when using a T1
network interface.