9. Factory default the Total Access 612/616/624 by one of the following methods:
Select S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
. At the > prompt, type factory_reset. You will then see
“Restore Factory Defaults and Reset Unit? (press
Y).” Press the Y key to confirm default. The unit
then resets.
If connected to the
CRAFT port (must be 9600 baud), power reset the unit and then restore power
to the unit while holding down the
F
key. You will then be prompted to confirm the factory default.
10. In the ATM code, the upgrade was successful if the S
YSTEM
I
NFO
> F
IRMWARE
R
EVISION
field does not
display Error.
11. Reconfigure the unit for the specific application.
Purchase of a T1 TDM 612/616/624 Unit with the EC/ADPCM Card Installed for Later Upgrade to ATM
For customers who plan to operate a TDM application initially, but eventually upgrade to an ATM
application, a Total Access 612/616/624 unit may be purchased with the EC/ADPCM card installed
(P/N 4200612L2#TDM, 4200616L2#TDM, 4200642L2#TDM).
1. When the circuit is converted to ATM, the customer may obtain the latest VoATM firmware from the
ADTRAN website (http://www.ADTRAN.com). Select S
UPPORT
> P
OST
-S
ALES
T
ECHNICAL
S
UPPORT
>
F
IRMWARE
U
PDATES
> 612/616/624 ATM or contact Post-Sales Technical Support at 888-4ADTRAN.
2. Upgrade the Total Access 612/616/624 with the latest VoATM firmware (see Updating the Firmware
using TFTP and DLP-8, Updating the Firmware using XMODEM for details on upgrading the
firmware).
3. Factory default the Total Access 612/616/624 by one of the following methods:
Select S
YSTEM
U
TILITY
> T
ERMINAL
M
ODE
. At the > prompt, type fac. You will then see “Restore
Factory Defaults and Reset Unit? (press
Y).” Press the Y key to confirm default. The unit then resets.
If connected to the
CRAFT port, power reset the unit and then restore power to the unit while
holding down the
F key. You will then be prompted to confirm the factory default.
4. In the ATM code, the upgrade was successful if the following two things occur:
•The S
YSTEM
I
NFO
> F
IRMWARE
R
EVISION
field does not display Error.