Section 4 User Interface Guide Total Access 600 Series System Manual
82 © 2004 ADTRAN, Inc. 61200624L1-1B
I
NTERFACES
(V35)
View the V.35 interface status and configure the V.35 parameters from this menu.
INTERFACES (V35) > CONFIG
Configure the DTE leads from this menu.
INTERFACES (V35) > CONFIG > CTS
Sets the control characteristic of the clear-to-send lead. Choices are
N
ORMAL
(follows RTS) or
F
ORCE
ON
.
Default is
N
ORMAL
.
INTERFACES (V35) > CONFIG > DCD
Sets the control characteristic of the carrier detect lead. Choices are
N
ORMAL
(follows valid signal on the
network interface) or
F
ORCE
ON
. Default is N
ORMAL
.
INTERFACES (V35) > CONFIG > DSR
Sets the control characteristic of the data set ready lead. Choices are N
ORMAL
(follows DTR) or F
ORCE
ON
.
Default is
N
ORMAL
.
INTERFACES (V35) > STATUS
View the status of the DTE leads from this menu.
INTERFACES (V35) > STATUS > RTS
View the status of Request to Send (RTS) lead. Possibilities are O
FF
or O
N
.
INTERFACES (V35) > STATUS > DTR
View the status of the Data Terminal Read (DTR) lead. Possibilities are O
FF
and O
N
.
INTERFACES (V35) > TEST
These options are used to loopback tests.
INTERFACES (V35) > TEST > LOOPBACK
Enables a local loopback of the V.35 interface. All data received on the V.35 interface is transmitted back out
the interface.
I
NTERFACES
(FXS)
View the FXS interface status and configure the FXS parameters from this menu.
INTERFACES (FXS) > CONFIG
Configure the FXS mode, line impedance and Tandem parameters from this menu.