Enable / Disable Parameter Scanning
Use this parameter to decide whether scanner parameters can be set using the bar codes in this chapter.
When this parameter is disabled, scan the Set All Defaults parameter bar code to enable parameter scanning.
When disabled, either scan the Enable Parameter Scans bar code or the Set All Defaults bar code to reset the parameter.
When enabled, scanners can be configured using the bar codes in this chapter.
Select a mode by scanning either of the bar codes shown below.
Imager Parameters – General
Except for the General imager attributes in this section that can be set by the end-user, imager programming attributes are set
using the bar code wedge panel (Control Panel Scanner or Data Collection wedge panel) resident on the host mobile device.
Bar code manipulation parameters assigned using the Bar Code Wedge panels are applied to the data resulting from successful
bar code scans.
Decode Session Timeout
Default: 9.9 Seconds
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 sec-
ond increments from 0.5 to 9.9 seconds. If a label has not been decoded before this time expires and the session is termi-
nated, the software regards it as a failed scan attempt.
To begin setting a decode session time-out in seconds, scan this Decode Session Timeout bar code:
Next, scan two numeric bar codes that correspond to the desired time-out using Imager Keypad Number Symbols (page 5-
81).
Times less than 1.0 second must have a leading zero.
If you wish to change your number selection, scan Cancel on the Imager Keypad Number Symbols page.
* Enable Parameter Scans
Disable Parameter Scans