15
WIRING/SCHEMATIC DIAGRAMS
WIRING SCHEMATIC
WIRING / COMPONENT DIAGRAM
L1
N
1. PUR - FLAME SENSOR
2. GRN - GROUND
3. BLU - GAS VALVE (TERM #1)
4. ORG - THERMOSTAT
5. (BLANK)
6. BLK - 24 VAC
7. RED - IGNITER
F
LAME
S
ENSOR
SHORT TO BYPASS
FLAME SENSOR
GAS
VALVE
#
2 #1
IGNITER
FUSE
10 AMP - 32 VOLT
24 VAC
120 VAC
60 Hz
SW
N
L1
FUSE
1
2
3
4
5
6
7
1
2
GROUND
LUG
IGNITION
MODULE
FLAME
SENSOR
MINI
IGNITER
GAS
VALVE
24 VOLT AC
TRANSFORMER