Back-UPS® RS Installation and Operation
5
Function Button Quick-Reference
Function Button
Timing
(seconds)
UPS
Status
Description
Power
Power On
0.2 Off
Press
POWER to start receiving input utility power. If A/C input
power is not available, the unit will run on battery power.
Power Off
2On
The unit is not receiving input utility power, but is providing
surge protection.
Display
Status Inquiry
0.2 On
Verify the status or condition of the unit. The LCD will illuminate
for 60 seconds.
Full-Time/Power-
Saving mode
2On
The LCD will illuminate and the unit will beep to confirm the
Full-Time mode. The LCD will darken and the unit will beep to
confirm the Power-Saving mode. While in Power-Saving Mode,
the LCD will illuminate if a button is pressed, then darkens after
60 seconds of no activity.
Mute
Event Specific
0.2 On
Disable any audible alarms caused by an event.
General Status Enable/
Disable
2On
Enable or disable the audible alarms. The Mute icon will
illuminate and the unit will beep one time. The Mute function will
not activate unless the UPS is operating on battery power.
Sensitivity
6Off
The Load Capacity icon will blink, indicating that the unit is in
programming mode. Use the
POWER button to scroll through
Low, Medium, and High, stop at selected sensitivity. The unit will
beep to confirm selection. See Configuration for details.
Master/Controlled
outlet Enable/Disable
2On
The leaf icon will darken indicating that the Master Outlet feature
is disabled or illuminate to indicate the Master Outlet feature is
enabled. The unit will beep once.
Master/Enable
Threshold
Calibration
6On
While calibrating the threshold setting, the device connected to
the Master Outlet should be turned off or placed in Standby or
Sleep mode. Upon completion, Power-Saving icon will flash 3
and beep 3 times.
Self-Test (manual)
6On
The UPS will perform a test of the internal battery. Note: This
will happen automatically when the unit is turned ON.
Event Reset
0.2 On
When the Event screen is visible, press and hold
DISPLAY, then
press
POWER, to clear the utility failure event counter.
Fault Reset
2Fault
After a fault has been identified, press
POWER to remove the
visual indication and return to standby status.