0

Out of 0 Ratings

Owner's of the Chamberlain Universal Remote Clicker Klik1u Universal Remote Control gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 2
 
ON
2 3
1
KG
KG
12 11 10 9 8 5 3 7 6 4 1 2
CLICKER
®
MODEL KLIK1U
UNIVERSAL GARAGE DOOR OPENER REMOTE CONTROL
Read instructions thoroughly BEFORE beginning.
Start with garage door closed. Identify garage door opener type - Smart/Learn button
or DIP Switch. Smart/Learn button or DIP Switches are located on motor unit or
external receiver. Refer to owner’s manual if necessary.
Clicker products are intended to be used only with garage door openers
manufactured after 1993 that utilize photo-eyes safety sensors. These are always
located on or near the bottom of the door track. If your garage door does not
have the sensors attached and working, the opener is not compliant with current
federal safety regulations and should be replaced.
Proceed with instructions according to your type of garage door opener.
To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:
ALWAYS keep remote controls out of reach of children. NEVER permit children to
operate, or play with remote control transmitters.
Activate gate or door ONLY when it can be seen clearly, is properly adjusted and
there are no obstructions to door travel.
ALWAYS keep gate or garage door in sight until completely closed. NEVER permit
anyone to cross path of moving gate or door.
© 2011, Clicker Corporation
114A3485G All Rights Reserved
OR
DIP SWITCH SMART/LEARN BUTTON
REMOTE CONTROL BATTERY
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver
and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE
NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Dispose of batteries properly. Replace ONLY with 3V2032 coin batteries.
To prevent possible SERIOUS INJURY or DEATH:
NEVER allow small children near batteries.
If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
Replace ONLY with 3V2032 coin batteries.
DO NOT recharge, disassemble, heat above 100° C (212° F) or
incinerate.
Chamberlain, LiftMaster and Moore-O-Matic are Trademarks of Chamberlain Group.
Genie and Intellicode are trademarks of GMI Holdings, Inc. Overhead Door is a
Trademark of Overhead Door Corporation. Linear is a Trademark of Linear Corporation.
Master Mechanic is a Trademark of TruServ. Sears is a Trademark of Sears &
Roebuck. Stanley is a Trademark of The Stanley Works. Wayne Dalton is a trademark
of Wayne Dalton Corporation. Do It is a trademark of Do It Best Corporation.
DIP SWITCH SMART/LEARN BUTTON
3
Press program button until
LED lights.
1
See Chart A to determine
# of times to press
button and write in blank
on Step 5.
1
See Chart B to determine
# of times to press
button and write in blank
on Step 5.
* NOTE: LiftMaster, Do-It, Master Mechanic, Raynor, True Value and Sears Craftsman are compatible with
Chamberlain technology.
**NOTE: Visit www.clickerproducts.com for Genie Intellicode II instructions.
Product Registration and Troubleshooting
www.clickerproducts.com • 1-800-442-1255
LED Indicator
Button 1
Button 2
Program Button
Battery
DIP Switches
Battery Cover
NOTE:
2 Position DIP Switch:
If programming fails reverse
DIP switches (OFF to ON and
ON to OFF).
** 3 Position DIP Switch:
For Chamberlain remotes DO NOT
use the “0” position, use “+” or “-”. If you already have
a 3-button remote, DIP switch #1 must be set to “-” if
the large button is to open the door. It may be
necessary to reprogram original remote controls.
ON
STOP
CHART B
# of times to
press button Brand Description Year
11 Chamberlain
®
* 9 Position '90-'92
12 Chamberlain
®
*
9 Position
Canada
'83-'89
13 Genie
®
12 Position '85
14 Linear Multicode
®
10 Position '76
15 Chamberlain
®
8 Position '83-'89
16
Stanley/
Multicode
®
10 Position '76
17 Genie
®
9 Position '85
18
Linear
®
Moore-O-Matic
®
8 Position '76
19 Chamberlain
®
7 Position '83-'89
CHART A
# of times to
press button Brand
Type/Color of
Smart/Learn Year
1 Linear
®
Mega-Code '97-Current
2 Chamberlain
®
* Orange/Red '97-'03
3 Chamberlain
®
* Purple '05-Current
4 Chamberlain
®
* Green '93-'96
5
Genie
®
Overhead Door
®
Intellicode '95-Current
6
Genie
®
**
Overhead Door
®
Intellicode '93-Current
7 Stanley
®
Secure Code '98
8 Chamberlain
®
* Yellow '11-Current
9 Wayne Dalton
®
Rolling Code '99
11 Chamberlain
®
9 Position '90-'92
2
2
Programming complete. Press
selected button to test. If unit
does not work, return to Step 3.
7
Programming complete. Press
selected button to test. If unit
does not work, return to Step 3.
7
Press program button.
6
Press program button.
6
5
OR
OR
Click
NOTE: If there are problems
programming to button 1,
program to button 2.
Select a button to program.
Press button times ensuring
LED stops flashing after each
press. Code is accepted when
one of the following occurs:
2 3
1
KG
KG
Press and release the Smart/
Learn button.
Motor Unit
4
12 11 10 9 8 5 3 7 6 4 1 2
3
Match DIP switches. Turn
extra switches OFF.**
Motor
Unit
Existing
Remote
Clicker
Remote
4
Press program button
until LED lights.
5
Select a button to program.
Press button times
ensuring LED stops flashing
after each press. Code is
accepted when door
activates.
NOTE: Your opener may
appear different and you may
have to remove the light lens
to access the learn button.
2