0

Out of 0 Ratings

Owner's of the Casio Watch Casio Sgw300h-1av Wrist Watch gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 5
 
Operation Guide 3202
5
Troubleshooting
Time Setting
The current time setting is off by hours.
Your Home City setting may be wrong. Check your Home City setting and correct it, if
necessary.
The current time setting is off by one hour.
You may need to change your Home City’s standard time/daylight saving time (DST)
setting. Use the procedure under “To change the current time and date settings” to
change the standard time/daylight saving time (DST) setting.
Sensor modes
I can’t change the temperature, barometric pressure, and altitude units.
When TYO (Tokyo) is selected as the Home City, the altitude unit is set automatically
to meters (m), the barometric pressure unit to hectopascals (hPa), and the
temperature unit to Celsius (°C). These settings cannot be changed.
The battery indicator (
) appears while a sensor operation is being
performed.
The battery indicator appears in the upper left corner of the digital
display whenever there is not enough battery power available to
perform a sensor operation in the Barometer/Thermometer Mode
or Altimeter Mode. Sensor operation is disabled while the battery
indicator is displayed.
Normal operation should return after battery power recovers.
“ERR” appears while a sensor operation is in progress.
Subjecting the watch to strong impact can cause sensor malfunction or improper
contact of internal circuitry. When this happens, ERR (error) will appear on the display
and sensor operations will be disabled.
Barometric
Pressure/Temperature
Measurement
Altitude
Measurement
If
ERR
appears while a measurement operation is being performed in a sensor mode,
restart the measurement. If
ERR
appears on the display again, it can mean there is
something wrong with the sensor.
Barometer/Thermometer Mode and Altimeter Mode sensor operations are disabled
whenever there is not enough battery power available to perform a sensor operation.
This is true regardless of the current battery level. In this case,
ERR
will appear on
the display. This does not indicate malfunction, and sensor operation should resume
once battery voltage returns to its normal level.
If
ERR
keeps appearing during measurement, it could mean there is a problem with
the applicable sensor.
Whenever you have a sensor malfunction, take the watch to your original dealer or
nearest authorized CASIO distributor as soon as possible.
The barometric pressure differential pointer does not appear on the display
when I enter the Barometer/Thermometer Mode.
This could indicate sensor error. Try using
C
to re-enter the Barometer/
Thermometer Mode.
The barometric pressure differential pointer is not displayed when the displayed current
barometric value is outside of the allowable measurement range (260 to 1,100 hPa).
World Time Mode
The time for my World Time City is off in the World Time Mode.
This could be due to incorrect switching between standard time and daylight saving
time. See “To specify standard time or daylight saving time (DST) for a city” for more
information.
Specifications
Accuracy at normal temperature: ±30 seconds a month
Timekeeping: Hour, minutes, seconds, p.m. (P), month, day, day of the week
Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 48 city codes); Standard Time /
Daylight Saving Time (summer time)
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference
altitude
Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference
altitude or due to atmospheric conditions.
Display unit: 5 m (or 20 ft.)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours
Other: Reference altitude setting
Barometer:
Measurement and display range:
260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display unit: 1 hPa (or 0.05 inHg)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours in the Barometer/Thermometer Mode
Other: Calibration; Barometric pressure differential pointer
Thermometer:
Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute
interval for next 10 hours
Other: Calibration
Battery indicatorBattery indicator
Pressure Sensor Precision:
Conditions
(Altitude)
Altimeter Barometer
Fixed
temperature
0 to 6000 m
0 to 19680 ft.
± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.
± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg
6000 to 10000 m
19680 to 32800 ft.
± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.
Effect of
variable
temperature
0 to 6000 m
0 to 19680 ft.
± 50 m every 10°C
± 170 ft. every 50°F
± 5 hPa every 10°C
± 0.148 inHg every 50°F
6000 to 10000 m
19680 to 32800 ft.
± 70 m every 10°C
± 230 ft. every 50°F
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Precision is lessened by strong impact to either the watch or the sensor, and by
temperature extremes.
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)
World Time: 48 cities (31 time zones)
Other: Daylight Saving Time/Standard Time
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two finishes
Countdown Timer:
Measuring unit: 1 second
Countdown start time setting range: 1 minute to 24 hours (1-hour increments and
1-minute increments)
Alarms: 5 Daily alarms; Hourly time signal
Illumination: LED (Light-emitting diode); Selectable illumination duration
(approximately 1 second or 3 seconds)
Other: Low-temperature resistance (–10°C/14°F); Button operation tone on/off
Battery: One lithium battery (Type: CR2016)
Approximate battery operating time: 3 years under the following conditions:
1 illumination operation (1.5 seconds) per day
10 seconds of alarm operation per day
10 hours of altimeter measurement, once per month
Frequent use of illumination runs down the battery.
City Code Table
City
Code
City
UTC Offset/
GMT Differential
PPG Pago Pago –11
HNL Honolulu –10
ANC Anchorage –9
YVR Vancouver
–8
LAX Los Angeles
YEA Edmonton
–7
DEN Denver
MEX Mexico City
–6
CHI Chicago
NYC New York –5
SCL Santiago
–4
YHZ Halifax
YYT St. Johns –3.5
RIO Rio De Janeiro –3
FEN
Fernando de
Noronha
–2
RAI Praia –1
UTC
0LIS Lisbon
LON London
MAD Madrid
+1
PAR Paris
ROM Rome
BER Berlin
STO Stockholm
ATH Athens
+2CAI Cairo
JRS Jerusalem
City
Code
City
UTC Offset/
GMT Differential
MOW Moscow
+3
JED Jeddah
THR Tehran +3.5
DXB Dubai +4
KBL Kabul +4.5
KHI Karachi +5
DEL Delhi +5.5
KTM Kathmandu +5.75
DAC Dhaka +6
RGN Yangon +6.5
BKK Bangkok +7
SIN Singapore
+8
HKG Hong Kong
BJS Beijing
TPE Taipei
SEL Seoul
+9
TYO Tokyo
ADL Adelaide +9.5
GUM Guam
+10
SYD Sydney
NOU Noumea +11
WLG Wellington +12
Based on data as of December 2009.
The rules governing global times (GMT
differential and UTC offset) and
summer time are determined by each
individual country.