Installation Guide Back-UPS BE750G Series4
Turn On the Back-UPS
Press the Power ON button located on the top of the Back-UPS. The Power On/Replace Battery LED will
illuminate green and a single short beep will be audible to indicate that the Back-UPS is providing protection for
connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to utility power. The Back-UPS
battery will charge while the Back-UPS is switched on or off and is connected to utility power. Do not expect full
battery run capability during the initial charge time.
If the red Building Wiring Fault LED located on the side of the Back-UPS illuminates, do not operate the
Back-UPS. Have a qualified electrician correct the building wiring fault.
Operation
Energy Saving Master and Controlled by Master Outlets
When this feature is enabled, a device plugged into the MASTER outlet will act as the master on/off switch for
devices plugged into the CONTROLLED BY MASTER outlets. Turn off or place in Standby mode the device
plugged into the MASTER outlet and automatically all devices plugged into the CONTROLLED BY MASTER
outlets will turn off. When the device plugged into the MASTER outlet is turned on or is taken out of standby
mode, all devices plugged into the CONTROLLED BY MASTER outlets will automatically turn on.
Press and hold the Enable Master button for one second to enable or disable the feature. The Enable Master LED
will illuminate green when the feature is enabled. There is no LED illumination when the feature is disabled.
Program the Threshold Settings
Some computers consume so much power that the MASTER outlet does not recognize the reduced power level of
standby mode. In this case the CONTROLLED BY MASTER outlets will not shut off power to connected
devices. When this occurs the threshold setting should be adjusted. Before adjusting the threshold setting verify
that the Enable Master LED is illuminated green.
If the devices connected to the CONTROLLED BY MASTER outlets do not shut down when the MASTER
device goes into Standby mode, increase the threshold setting to high.
To change the threshold setting:
1. Plug the Back-UPS into a wall outlet. Do Not turn on the Back-UPS. The Back-UPS will be in Standby
mode and no LEDs will be illuminated.
2. Press and hold the
ENABLE MASTER button for 10 seconds, after which all the LEDs will flash.
The Back-UPS is now in Threshold Program mode.
3. Release the
ENABLE MASTER button and the LEDs that remain illuminated indicate the current threshold
setting.
4. Press the
ENABLE MASTER button to change the threshold setting.
Refer to the table below for threshold settings.
Illuminated LED Flashes Threshold Setting
Input wattage Range in
Standby/Sleep Mode
Master Enable LED Low 10 Watts
Master Enable LED, OnLine LED Medium (factory default setting) 25 Watts
Master Enable LED, OnLine LED,
Replace Battery LED
High 60 Watts